博文

目前显示的是标签为“surgery light”的博文

The development trend of surgical lamps

图片
  Surgery lamps are different from ordinary lighting fixtures. The requirements for shadowless lamps are very special. They are strictly required in all aspects, and general lamps are irreplaceable. Surgical lights need to have good color rendering index, color temperature, illumination, temperature rise control and good heat dissipation design, and a very important part is the streamlined design of the overall product. Mingtai surgery lamp meets the market demand. The following is a brief introduction about Mingtai product features. 1.        Shadowless illumination: The shadow is immediately dimmed by the light from the illuminated area, regardless of the surgical position. The symmetrical shape of the light provides a perfect shadow control thanks to overlapping light techniques. 2.        Five-star laminar flow effect: cold flow design. Smooth surface. 24% of the turbulence is much lower than the DIN1946. There is...

Why is the operating light so popular in medical institutions?

图片
Surgery light is very important for the medical industry. It is a great guarantee for doctors to carry out surgery safely. With the continuous improvement of the surgical lamp technology, its function has been fully utilized. So, besides the above points, what are the reasons why it is popular? Small size and easy to install. Compared with the traditional ceiling-mounted shadowless lamps , the mobile shadowless lamp takes only a few minutes from unpacking to installation, which saves labor costs. And at the same time, the mobile shadowless lamp can be moved from one operating room to another, which greatly facilitates the medical staff to carry out surgery. Reasonable price. The price of double dome surgical lamp is often high for small clinics, but single dome surgery lamps are quite cost-effective. And when performing simple surgery, its illumination is no less than other surgical lights. In fact, during the operation, there are often unexpected situations, such as tripping ...

What are the new requirements of LED medical light in today's medical environment?

图片
LED medical light plays a very important role in medical industry. With the development of medical device, it design requirement also is improved. Then, under the current social development trend, what requirements should be met for the design of LED surgical lamps ? 1. LED shadowless light intensity should be suitable for the needs of the simple operating room Some simple operating rooms have poor lighting requirements, when choosing operating light, you need to consider its illuminance firstly. Generally the single dome operation lamp illuminance can reach 150,000 Lux. If you have enough budget, another satellite light can be chosen as auxiliary light, maximize the elimination rate. 2. The power of LED operation lamp should meet the power supply standard of simple operating room Too high or too low voltage can cause the surgical shadowless lamp to be unusable, resulting in the burning of the components inside. 3. Whether the LED surgery light can be moved in simple oper...

Why is it recommended to use LED light source as the first choice for shadowless lamps?

图片
In order to maintain good and stable operating room light environment, the operating room should be protected from direct sunlight, or colored glass can be used to facilitate artificial lighting. Due to the high illumination requirements of the operating room, the installation position of the lamps is often limited by the number and location of the air outlets and other equipment. This is not only asked to meet the high illumination, but also the number of lamps should be limited to the appropriate range, and the energy consumption of the operating room air conditioner should be taken into consideration. The heat of the bulb should be as small as possible. It is recommended to use LED light source. Since the LED is cold light source, there is almost no temperature rise in the room, the patient has no uncomfortable feeling, and the risk of dehydration caused by the light source is avoided. In addition, it can also reduce the energy consumption of indoor air conditioners properly; th...

What is the auxiliary surgery light advantage?

图片
Most people are familiar with ceiling surgery light , but for operating light, there are also have other types, such as wall mounted operating light, mobile shadowless lamp. Those operation lights can bring great convenience in the right environment. Today Shandong Mingtai company glad to introduce mobile operating light to you Mobile surgical lamp is one type of auxiliary surgical lamp. Its advantages are as below: 1. Small size and easy to install Compared with ceiling operating light , mobile operating lamp only needs few minutes to install it, saving labor cost. And in underdeveloped areas of medical care, mobile surgery lamp can be moved from one operating room to another operating room, very convenient for medical staff to carry out surgery. 2. Competitive price For some small clinics, the price of overall reflection shadowless lamp is too high. The mobile operating light not only can be moved easily, but also has competitive price. And it illumination is not less th...

Suggestion for purchasing surgery light

图片
First of all, when you choosing surgery light , you should not only notice its performance, but also pay attention to its safety, whether it is strictly implemented in the manufacturing according to the relevant safety standards, these two are more important. Secondly, you can’t just look at the appearance of the medical light when you choose it, the appearance of shadowless lamp is very importance for us, but the biggest role of the operating lamp is to help us to control the surgical field more accurately during the operation. If surgical light is only good-looking, color reproduction and illumination parameters are out of the industry standard, this will not guarantee the safety of our surgery. 1. Safety For medical devices, safety is always the most important goal. The safety here refers not only to the goods themselves, but also to the safety of the users and the objects they use. At present, the domestic and foreign standards of operation lamps are very mature, and some...

What are the main features of LED surgery light?

图片
LED surgery light is a device that is often used, the main function is to illuminate the surgical field to best observe small, low-contrast objects at different depths in the incision and body cavity. Since the doctor's head, hands, and instruments can cause shadows on the surgical field, the shadowless light should be designed to minimize shadows and minimize color distortion. In addition, it must be able to continue working for a long time without emitting excessive heat, because overheating can make the operator uncomfortable, it will also dry the tissue in the surgical field, which is not conducive to the rehabilitation of the patient. Shandong Mingtai company will introduce the product features of the operating lamp to you. It has the characteristics of energy saving, environmental protection, safety, long life, low power consumption, low heat, high brightness, waterproof, miniature, shockproof, easy dimming, concentrated beam, easy maintenance. The working voltage is ve...

LED shadowless lamp common fault solution

图片
LED shadowless lamp is a medical lighting tool used by medical personnel to observe the incision of the surgical field and different depths of tissue in the body cavity. Shadowless lights often have a variety of sudden failures during use. Mingtai Company summarized the common faults of LED operating light for everyone. 1. The main light is off and the auxiliary light is on. ZF series operation light has automatic switching function in the circuit control. When the main lamp is damaged, the auxiliary lamp will light up to ensure normal operation. After surgery, the main lamp bulb should be replaced immediately. 2. Light is not on. Open the top cover, check the transformer and power supply voltage to see whether thay are normal, if both are no problem, please find a professional to repair. 3. Transformer damage. There are generally two reasons for transformer damage: Supply voltage and excessive current caused by short circuit. The latter should ask a professional to repair. ...

LED operating light main feature

图片
LED medical light is widely used in hospital, the main function is to illuminate the surgical field to optimally observe small, low-contrast objects at different depths in the incision and body control. Since the operator's head, hands, and instruments may cause shadows on the surgical field, the surgery light should be designed to minimize shadows and minimize color distortion. In addition, it must be able to continue working for a long time without emitting excessive heat, because overheating can make the patient uncomfortable, it will also dry the tissue in the surgical field, which is not conducive to the patient's recovery. Shandong Mingtai company glad to introduce operation light advantage to you. With the features of energy saving, environmental protection, safety, long life, low power consumption, low heat, high brightness, waterproof, miniature, shockproof, easy dimming, concentrated beam, easy maintenance; The working voltage is very low and the working curren...

How important is the shadowless light for surgery?

图片
Firstly, surgery light is lighting equipment which us widely used in hospital, it is necessary lighting equipment for modern operating room. It is suitable for different surgeries, such as brain surgery and thoracic surgery. Secondly, why does surgery need medical light ? Everybody knows that the light source illumination in our daily life will show a shadow, it doesn’t have big effect on our lives. But if we use ordinary light in surgery, the shadow of the medical staff will be presented, maybe the surgery field will be blocked, which will affect surgery. Thirdly, operation light is not only without shadow. To meet the surgery requirement, shadowless lamp is not only required to eliminate shadows as much as possible, reduce the distortion of color, but also maintain long-term work. Some operations require more than ten hours of continuous work, if the situation is urgent, the surgical shadowless lamp must be able to work continuously for dozens of hours or even hundreds of hou...

How to extend the life of shadowless lamps?

图片
If you do not check and maintain the equipment after the surgery light is bought, it will cause frequent failures, makes its life greatly reduced. So how to extend the life of operating light ? 1. Periodic inspection, once a year. Check the connection status of each connection part of the shadowless lamp , prevent accidents caused by loose parts. After the operation is completed, the power must be turned off 2. To change the fuse, you must turn off the power. Replace the fuse of the same model. When changing the lamp bulb, you must first cut off the power supply and wait until the lamp bulb has cooled before replacing it. When the filter glass is damaged, the factory should be promptly repaired, otherwise it may cause burns of the body tissue. 3. Replace the lamp bulb, first cut off the power, then remove the disinfection handle, and then use a screwdriver to remove the light source system. The damaged bulb can only be replaced after it has been determined that the lamp has co...

The usage of internal camera surgery light

图片
With the development of medical industry, surgery lights are widely used in operating room, and it plays very important role. The camera is installed in the central handle of operating light , it includes one handle and one fixed disk, the handle is tubular housing, there is internal gear at one end. The outer ring of fixed disk is fixed, inner ring can be rotated, it is set in the handle. a circuit board and a lamp holder lifting mechanism are arranged above the outer ring; the camera in installed in the operation lamp handle, connected with fixed disk inner ring. Separating the camera and the rotating mechanism of the handle with fixed disk, using the gear set inside the handle and the belt drive, the rotation of the handle is linked with the lifting mechanism of the lamp holder, therefore, when the handle is rotated to adjust the illumination range of the surgical light , the fluctuations of the camera screen can be avoided.

Why more and more hospitals choose LED surgery lamps?

图片
LED surgery lights are being used more and more in hospitals, so why are they being used by more and more hospitals? What is its advantage? The LED shadowless light produced by Shandong Mingtai Medical Equipment Group Co., Ltd shell is aluminum alloy material, streamlined ultra-thin design, smaller air resistance, curve and smooth surface prevent the deposition of dust, purified air can reach the surgical wound much easily. As operating light illuminant source, LED bulb has those advantage of environmental, lower energy consumption and long lifetime. LED do not engender infrared ray and ultraviolet radiation, it doesn`t have the temperature rise and tissue damage caused by halogen shadowless light, can accelerate the wound healing after surgery, and has no radiation pollution. The handle on the central of operation lamp can be detachable, can take high temperature sterilization treatment, easily adjust, flexible fixed; there is control panel located in the big and small C...

What should be noticed when using LED operating light?

图片
LED surgery lamp is often used in hospital, medical staffs are very similar with it, it main function is to light the surgical field to facilitate observation of objects with low contrast at different depths in the incision and body cavity. Surgery lights are very important equipment during the operation, so what should you pay attention to in daily use? 1. The medical light should be repaired by professional. Non-professionals should not disassemble it or control circuits. 2. Often check the operating light screw to see whether it is loose, to prevent falling. 3. When adjusting the brightness of operation lamp , it should be adjusted from weak to strong. It is forbidden to open it to max large brightness to avoid damage to the bulb. 4. Adjust the position of the surgical lamp to avoid collision with medical pendant or the infusion stand to prevent damage. 5. The brightness of LED medical light brightness should be adjusted to the weakness after surgery, and then power off. 6. Lamp ...

The position of the surgery light in the operating room is very particular

图片
It is well known that the construction of hospital lighting system is a very complicated systematic project, there are many places should be paid attention to, there are also high requirements for lighting. In order to maintain a good and stable operating room light environment, the operating room should be protected from direct sunlight, it can also be covered with tinted glass to facilitate artificial lighting. The artificial lighting in the operating room is divided into general lighting, operating table key lighting, viewing light lighting, signal lighting and so on. Operating room general lighting requirements are higher, however, the installation position of the lamp is often limited by the number and location of air outlets and other equipment, this not only meets the requirements of the specified high illumination, but also limits the number of lamps to an appropriate range, while taking into account the requirements for air conditioning energy saving in operating room, the hea...

Surgery light LED bulb advantage

图片
LED surgery light has below advantage: 1. Small size The LED bulb on the surgery shadowless light is basically a very small wafer that is encapsulated in epoxy, so it is very small and light. 2. Low power consumption LED bulb has very low power consumption. Generally LED working voltage is 2-3.6V, working current is 0.02-0.03A, it means that it consumes is less than 0.1W. LED has obvious skill advantage compared with general operating light . 3. Long lifetime Mobile operation lamp LED bulb is solid cold light source, epoxy encapsulated, there are no disadvantages such as filament burning, heat deposition, and light decay. It lifetime can reach 60,000 to 100,000 hours, which is more than 10 times longer than traditional light sources. 4. Conducive to environmental protection There are no ultraviolet and infrared rays in the surgery light spectrum, neither heat nor radiation, little glare, and waste can be recycled, no pollution, no mercury element, cold light source...

Cold light source surgery light performance advantages

图片
The so-called cold light surgery light is a new type of high-tech light source that emerges after light sources such as incandescent lamps, LEDs, and LCDs. When the light is emitted, its temperature will not be higher than the ambient temperature, and the temperature rise of the lighting environment will not be continuously increased. It is also called cold light emission. Now the clinical operation time is as short as half an hour and as long as eight hours or more. During this period, hard work is not only the anesthetic patient, but also the doctor with a high degree of concentration under shadowless lights . If operating light light source don’t have cold light feature, operating room temperature will continuously increase; On the other hand, certain unstable clinical factors may also occur in the lesion tissue that is directly irradiated by the light source. Cold light operation light has below advantage: 1. Adapt overall reflection system which is made by CAD/CAM, max lig...

Surgery light main raw material introduction

图片
The main raw materials for surgery lights include cold-rolled steel plates, cold-rolled steel pipes, and engineering plastics. In recent years, medical device manufacturers who focus on the mid-to-high end market often use raw materials from high-quality steel mills, such as Shandong Mingtai company, they “strictly in and strictly out” on the selection of raw materials, laying a solid foundation for high quality in the future. Cold-rolled steel plate has the advantages of high strength, good toughness, smooth surface and strong corrosion resistance, therefore, it is widely used in surgical instruments such as shadowless lamps that require high mechanical performance and appearance. If hot rolled sheet is used in the production of shadowless lamp , the appearance will appear stiff and rough, and it is more likely to rust. At this stage, the stamping parts of most operating lights in China, such as lampshades and spring arms, are made of domestically produced high quality SPCC cold...

Camera surgery light structural features

图片
Camera surgery light has below features: 1. operation lamp camera system includes operation lamp , video cameras, multimedia computer digital monitoring systems and monitors 2. Internal camera system is installed in the central of handle, reliable, beautiful and flexible. 3. External camera system is installed in an independent arm, 360 degree rotation, the image is much better. 4. Adopting imported brand intelligent camera, high definition; 480 high lines, super dynamic; optical zoom, auto iris, auto white balance. The digital control host adopts H264 compression method with higher resolution. With single/multi-screen real-time preview, switching display; automatically store images, video playback, remote network transmission and other functions.

Laminar flow operating room requirements for surgery light

图片
Laminar purification is an air purification technology that creates high efficiency and rapid sterilization effect, it is currently widely used and maintained clinically. The design principle of laminar flow purification is in line with the requirements of the operating room, can effectively maintain the cleanliness of the indoor environment, and the humanized interior design meets the overall requirements for the modern operating room. However, laminar purification technology is not a panacea. It must rely on strict management systems and operational procedures to achieve the purpose of purifying the air. The selection of surgery light in laminar flow rooms also has quite strict requirements: Operating light is also different from ordinary light, it has very strictly requirement. It should have good CRI, color temperature, illumination, temperature rise control and thermal design, another important part is the streamlined design of the overall product. In order to comply with st...