博文

目前显示的是标签为“surgical lamp LED”的博文

The development trend of surgical lamps

图片
  Surgery lamps are different from ordinary lighting fixtures. The requirements for shadowless lamps are very special. They are strictly required in all aspects, and general lamps are irreplaceable. Surgical lights need to have good color rendering index, color temperature, illumination, temperature rise control and good heat dissipation design, and a very important part is the streamlined design of the overall product. Mingtai surgery lamp meets the market demand. The following is a brief introduction about Mingtai product features. 1.        Shadowless illumination: The shadow is immediately dimmed by the light from the illuminated area, regardless of the surgical position. The symmetrical shape of the light provides a perfect shadow control thanks to overlapping light techniques. 2.        Five-star laminar flow effect: cold flow design. Smooth surface. 24% of the turbulence is much lower than the DIN1946. There is...

The wrong way of using surgical light and how to maintain it

图片
As a medical device which is widely used in medical units today, the surgical lamp LED has the advantages of low maintenance cost, simple construction, high safety and long service life, so it has gradually won the recognition and favor of more and more people in the industry. However, it is still very difficult to avoid the damage caused by the wrong operation. Therefore, it is very important to know in advance the damage caused by the wrong operation of the halogen shadowless lamp and to do the inspection work. Below, it is up to Mingtai company to give you a simple science, I hope everyone will be interested. Operating light wrong operation: 1.        The height of the lamp head does not fit the proper position; the lamp head is at least 2 meters above the ground. 2.        The base is not properly placed, there is no guarantee that the respective functions do not interfere with each other, it is not convenient for...

Surgery lamp correct operation method

图片
LED operating light is widely used in hospital and clinic, it is fixed on the balance arm, can do vertical or horizontal movement, fix stable and move flexible, different height and angle can be met during surgery. Surgical light provides great convenience for doctors. In order to make the LED shadowless light better to play its advantages, the following is a detailed introduction to the precautions. Precautions for the use of surgical lamp: When using surgical lamp LED , the working distance should be maintained between 0.7 and 1.4 meters, and the temperature should be maintained between 10 and 40 degrees. The relative humidity in the operating room should be well controlled, not more than 75%. If the humidity is too high, it will cause damage to the operation lamp. Before using halogen shadowless lamp , you can wipe the surface of the bulb mirror with a soft cloth. Be careful not to wear the surface of the mirror.

How to properly inspect the surgical lamp?

图片
Surgical lamps are mainly used in the medical profession and are more common in hospitals. In order to protect its use, what we need to do is to check the surgical lamp LED regularly. Regarding the inspection of the halogen shadowless lamp , we still need to pay attention to some methods. Mingtai Company will give you a detailed summary of the inspection items related to operating lights. 1.        Grab the bottom of the bulb and enter the bulb holder directly during inspection. Be careful not to touch the glass on the reflective mirror surface of the bulb. It is recommended to wrap the bottom of the bulb with plastic or a clean cloth during installation and check if the bulb is installed. 2.        To extend the life of the bulb mirror surface, wipe it when necessary with soft, clean cloth and mild soap solution, do not wear the mirror surface. 3.        Operation light should be cleaned ...

Analysis of heat dissipation structure of surgical shadowless lamp

图片
Shadowless lamp is a common medical device for medical workers, many people are very familiar with some parameters such as color temperature and illuminance, but the heat dissipation method of the surgical lamp may not be well understood. Today, Shandong Mingtai Medical Group will introduce you to the cooling system of surgical lamp LED . With good convection heat dissipation, s urgical lamp  can provide good heat dissipation for surgical shadowless lamps, to ensure the normal illumination and the long service life of the operation light. It comprises cover, mirror with an opening at the top end, insulating glass, handle and light source assembly; The light source assembly includes a light source and a heat shield body having an opening portion and a bottom vent hole; Forming a convection passage between the mirror disposed in the outer cover and the outer cover; A compartment space is formed between the reflector and the insulating glass which is between the reflector and...