Why is it recommended to use LED light source as the first choice for shadowless lamps?
In order to maintain good and stable
operating room light environment, the operating room should be protected from
direct sunlight, or colored glass can be used to facilitate artificial
lighting.
Due to the high illumination requirements
of the operating room, the installation position of the lamps is often limited
by the number and location of the air outlets and other equipment. This is not
only asked to meet the high illumination, but also the number of lamps should
be limited to the appropriate range, and the energy consumption of the
operating room air conditioner should be taken into consideration. The heat of
the bulb should be as small as possible. It is recommended to use LED light
source. Since the LED is cold light source, there is almost no temperature rise
in the room, the patient has no uncomfortable feeling, and the risk of
dehydration caused by the light source is avoided. In addition, it can also
reduce the energy consumption of indoor air conditioners properly; the general
light CRI of the operating room should be close to natural light, preferably
between 4000 and 5000K, usually with a color rendering index of Ra≥90.
General lighting in the operating room
should not use traditional magnetic ballasts, operating light powered by
conventional magnetic ballasts will be strobed due to AC power. Doctors perform
surgery under this ever-changing stroboscopic light source. The visual system
needs to constantly adjust the size of the eyeball pupil to ensure the
stability of the retina illumination and imaging clarity. Long-term work will
inevitably make the pupil sphincter fatigue due to excessive use. It will have
an adverse effect on the surgery and will also cause some damage to the
doctor's vision.
The AC electronic ballast is a new type of
rectifier composed of rectification and filtering, high frequency oscillation
and rectifier coil protection circuit. Since the power frequency is greatly
increased to 55 kHz, even 80 kHz, 100 kHz super audio, the flicker frequency of
the surgery light
is correspondingly increased to the area where the human eye is not sensitive,
which alleviates the stroboscopic effect. At the same time, the buzzer
interference is completely eliminated, the power consumption is greatly
reduced, and the power factor of the operation lamp is improved. Electronic
ballasts have great advantages at low voltages, but unfortunately, the
ultra-high frequency also brings another adverse effect, that is,
electromagnetic interference generated by high-frequency oscillations, that is,
said that the higher the power frequency, the more serious the electromagnetic
radiation phenomenon. With the development of modern medical technology, the
precision electronic medical equipment used in the operating room is
increasing. The electromagnetic interference influence of many electronic
ballasts on the normal use of these devices cannot be ignored. For example, in
cardiothoracic surgery, when the patient installs pacemaker, it may also be
dangerous due to electromagnetic interference.
In summary, to solve these two problems, it
is recommended to use LED light source medical
light, LED working
mode is driven by external or built-in power supply, no ballast is needed, so
the problem of strobo can be effectively solved, the good quality LED lamp can
almost achieve no stroboscopic; In addition, the use of high-end isolated power
supply can effectively reduce the electromagnetic interference of the lamp for
precision instruments and prolong its life.