Medical pendant configuration

图片
Medical pendant configuration: 1. Surgical medical pendant : arm; CO2*2 (only emergency room, digital surgery room, endoscopic surgery room, endoscopic OR pendant and anesthesia hospital pendant); N2*1 (only ENT, endoscopic OR pendant + anesthetic surgical pendant; brain surgery, surgical medical pendant + anesthetic surgical pendant); negative pressure*2; grounded*2; 10A socket*8; RJ45*2; double tray, no drawer, pneumatic brake/mechanical damping, spring arm lift. 2. Endoscopy OR pendant : Adding video data interface and another tray on the basis of surgical medical pendant , the display support is installed on the shadowless lamp. 3. Anesthetic surgical pendant : arm, oxygen *2, air *1, anesthetic exhaust *1, negative pressure *2, RJ45*2, grounded *2, 10A socket *8; For column type, no tray, no anesthesia machine, pneumatic brake/mechanical damping, no electric lifting, brine rack. ICU surgery pendant configuration All ICU and thoracic surgery ICU use bridge pendant ...

Surgery light LED bulb advantage

图片
LED surgery light has below advantage: 1. Small size The LED bulb on the surgery shadowless light is basically a very small wafer that is encapsulated in epoxy, so it is very small and light. 2. Low power consumption LED bulb has very low power consumption. Generally LED working voltage is 2-3.6V, working current is 0.02-0.03A, it means that it consumes is less than 0.1W. LED has obvious skill advantage compared with general operating light . 3. Long lifetime Mobile operation lamp LED bulb is solid cold light source, epoxy encapsulated, there are no disadvantages such as filament burning, heat deposition, and light decay. It lifetime can reach 60,000 to 100,000 hours, which is more than 10 times longer than traditional light sources. 4. Conducive to environmental protection There are no ultraviolet and infrared rays in the surgery light spectrum, neither heat nor radiation, little glare, and waste can be recycled, no pollution, no mercury element, cold light source...

Operating table work system introduction

图片
As the key and important medical equipment in modern medical activities, OR table installation and usage attracts much attention. And its working system has important influence on medical activities and is therefore of comparative concern. Hydraulic system has those features of compact structure, small size, light weight, low noise, smooth control, easy installation and overall layout. Hydraulic system includes fuel tank, check valve, solenoid valve, relief valve, capsule accumulator, pressure gauge, throttle valve and cylinder. Capsule accumulator can be used as a power source for storing pressure oil and releasing energy when needed. According to the pressure gauge to achieve automatic compensation of pressure. The motors are driven independently by their respective drives. The surgical table is equipped with a hand controller for performing various motion controls. Each electric surgery table parameter is controlled by microprocessor. The microprocessor is connected to t...

What are the differences in medical pendant classification?

图片
The use of medical pendant in hospitals is increasing, and it can be seen in both wards and operating rooms. But this medical device is not universal, the medical bridge pendant purification level will be divided according to the location of use, the size of the purging area and ICU surgery pendant rotation arm arrangement are related to the installation position. As a gas supply and equipment-bearing medical equipment, the OT pendant has the function of line number management and the enhancement of laminar flow purification. It can create a more neat, high-utilization work space for medical staff to improve the convenience of medical staff. The pendant for hospital has different designs and functions according to the use of the department. The pendant are now generally divided into operating room pendant and ICU pendant. So what is the principle of choosing medical pendant for these two types of departments? Judging based on the type of surgery, surgery generally uses anesthe...

Cold light source surgery light performance advantages

图片
The so-called cold light surgery light is a new type of high-tech light source that emerges after light sources such as incandescent lamps, LEDs, and LCDs. When the light is emitted, its temperature will not be higher than the ambient temperature, and the temperature rise of the lighting environment will not be continuously increased. It is also called cold light emission. Now the clinical operation time is as short as half an hour and as long as eight hours or more. During this period, hard work is not only the anesthetic patient, but also the doctor with a high degree of concentration under shadowless lights . If operating light light source don’t have cold light feature, operating room temperature will continuously increase; On the other hand, certain unstable clinical factors may also occur in the lesion tissue that is directly irradiated by the light source. Cold light operation light has below advantage: 1. Adapt overall reflection system which is made by CAD/CAM, max lig...

Electric OR table structure and composition

图片
Generally, electro surgery table consists of table frame and other accessories. The table frame includes support section, transmission section and control section. Operating table support section, transmission section and control section are different according to different operation table manufacturer products. Generally the support section mainly includes three parts: table top, column part and base. The table top is composed of a plurality of support plates with different functions, such as head plate, back plate, waist bridge, hip plate and foot plate. The base part generally includes casters and brake locking devices. Surgery table transmission section can be divided into three kinds of transmission structure according to the transmission principle: hydraulic, mechanical and pneumatic. The hydraulic transmission structure generally includes cylinder, oil pump, solenoid valve, overflow valve, oil pipeline, hydraulic cylinder, etc. Mechanical transmission structures general...

Why should the outlet on the medical pendant distinguish between colors?

图片
The medical pendant is an indispensable gas supply and oxygen supply equipment for hospital operation rooms. It is mainly used for the transfer of medical gases such as oxygen and nitrogen in the operating room, safe and reliable, during emergency treatment, oxygen can be delivered to the patient in a timely manner, reducing the risk factor. Because the use scope of medical pendants is limited, people often lack sufficient knowledge about such medical products. But when people go to the hospital, they sometimes notice that the color of the power socket on the medical pendant is different. Why is the color of the power outlet on the medical bridge pendant different? Shandong Mingtai company glad to explain it for you: The appearance design of the medical pendant bridge pendant is very scientific and technical, it has strong practicality, and it also has a very beautiful and avant-garde appearance. The medical pendant has more functions to meet users' different needs that is w...

Notes on using OR table

图片
The OR table is an indispensable and important equipment for modern medical institutions to carry out medical activities. For the use of the device is more important, Mingtai will introduce you to the main usage precautions. 1. Press the power switch on the controller panel to enter the operation preparation phase. 2. Correct start and release of the base brake. 3. Prevent accidental injury: (1). Prevent dumping: Unlocking and fixing the electric operating bed after the base brake is turned on. At this time, operating the operating table or transferring the patient may cause the operation bed to shift and cause the patient to fall out of bed. Therefore, be sure to lock the operating table after completing the adjustment operation. (2) Prevent pinching or crushing: Do not put your feet under the base when releasing the base brake. (3). Prevent tripping: Put the wire in place to avoid tripping when walking. (4). Prevent electric shock: Do not operate or repair the surge...

Surgery light main raw material introduction

图片
The main raw materials for surgery lights include cold-rolled steel plates, cold-rolled steel pipes, and engineering plastics. In recent years, medical device manufacturers who focus on the mid-to-high end market often use raw materials from high-quality steel mills, such as Shandong Mingtai company, they “strictly in and strictly out” on the selection of raw materials, laying a solid foundation for high quality in the future. Cold-rolled steel plate has the advantages of high strength, good toughness, smooth surface and strong corrosion resistance, therefore, it is widely used in surgical instruments such as shadowless lamps that require high mechanical performance and appearance. If hot rolled sheet is used in the production of shadowless lamp , the appearance will appear stiff and rough, and it is more likely to rust. At this stage, the stamping parts of most operating lights in China, such as lampshades and spring arms, are made of domestically produced high quality SPCC cold...

How to ensure the performance of the OR table

图片
The installation and use of the OR table is more concerned and valued by the majority of medical institutions. In the daily use process, it is also crucial and important to ensure the operating performance of the operating table . Now Shandong Mingtai company glad to introduce it to you. 1. Cleaning and disinfection surgical beds and accessories: (1). Clean the operating table and accessories with a weak glass cleaner containing surfactants and phosphate gum (2). Sterilization of the operating bed should be diluted and disinfected with a surface disinfectant containing ethyl acetate. The mixture containing ecstasy should not be used to avoid corrosion of the metal surface. (3). Do not spray or rinse the base with detergent and clean water to prevent internal electrical control systems from shorting out, parts from rusting or malfunctioning. 2. Do not operate the hydraulic motor continuously for more than 5 minutes to avoid malfunction. 3. Do a good job in accessories man...

Medical bed installation notes

图片
1. When the lateral tilt function is needed, the medical bed surface must be in a horizontal position. Similarly, when the back board is raised and lowered, the lateral surface of the hospital bed must be lowered to a horizontal position. 2. Do not move on bumpy roads or park on sloped roads. 3. Annually add a little oil to the screw nut and pin shaft. 4. Please check the pins, screws, guardrails silk frequently to prevent loosening. 5. Do not push or pull the gas spring. 6. Screw and other transmission parts, please do not use force to operate. If fault occurs, please use after inspection. 7. Please use seat belts and prohibit children from operating.

Anesthesia medical pendant configuration principle

图片
1. The anesthesia medical pendant should be equipped with reasonable medical gas and electrical output terminals to meet the needs of the anesthesia machine and ensure the safety of doctors and patients; 2. Suspended anesthesia medical pendant should have enough net load, in order to ensure the improvement stability of the anesthesia machine, vertical lifting should be adopted; In order to prevent the anesthesia machine from drifting during operation, each arm joint should be equipped with pneumatic braking system; 3. Due to the high degree cleanliness of the Class-A operating room, auxiliary equipment takes big interior space, and the large number of medical personnel, the anesthesia medical pendant should be flexible enough to meet the needs of surgeons, ophthalmologists, and ENT surgeons. 4. According to the size of the operating room and the characteristics of specialist surgery, such as the operating room with an indoor area of less than 35m2 and a relatively fixed posit...